Chapter 4

Inspection Configuration

4–42

Configuring Subimage

The

Image Manager

provides a “pick and place” function to set the position

and size of the subimage window. To configure a subimage, pick the
button, then position the window over the appropriate feature in the image
field and set window’s size, as illustrated by the example in Figure 4.33.

Figure 4.33

Example: Subimage Window Positioned Over Feature

Subimage window

Before saving the feature image, check the

Default Device

field. Initially,

the default device is “

MC:

,” which is the memory card. If you expect to save

all (or most) feature image files in this device, leave it as “

MC:.

” If, however,

you want to use another device, you can change the default device by picking
the

Default Device

field and selecting another device from the

Devices

selection panel.

To save a feature image, pick the

button. When you do, the keyboard

panel appears with this instruction in the title bar:

Enter a file name. Default device is MC:.

To store an image file in the default device, enter a file name such as . . .

Feature1

Advertising