Rockwell Automation 5370-CVIM2 Module User Manual

Page 410

Advertising
background image

Chapter 7

Inspection Tools

7–172

Min+%Diff High Mode

When you pick

Min+%Diff High

in the

Thresh Mode

panel, the

Threshold

panel appears as shown in Figure 7.138.

Figure 7.138 Appearance of Threshold Adjustment Panel With Min+%Diff High Mode

In this mode, the slide bar has two cursors (the

%

and

High

cursors) and two

corresponding fields (the

%

and

Limit

fields). The default value for the “

%

field is 50, and the default value for the “

Limit

” field is 255.

The

Min+%Diff High

threshold mode enables you to set up a dynamic

threshold, along with a maximum limit above which the threshold may not go
during run mode operation.

The concept of the

Min+%Diff High

threshold mode is this: The profile tool

will find the minimum and maximum gray scale values on the profile display,
and then place the threshold at a position that is equal to the minimum value
plus 50% (default value) of the difference between the minimum and
maximum values, not to exceed an upper limit of 255 (default value).

The practical effect is this: During run mode operation, the threshold will
automatically readjust itself whenever lighting and other external
circumstances change, but it will not exceed the high limit value.