7–25

Fail –– This returns an “error code” when the tool is in a fail condition
and

0.000

for all other conditions. The error code identifies a specific

reason for the failure; for example, error code

1045.000

identifies “High

range fail” as the cause of the inspection failure. The complete list of
error codes and fail conditions appears in Appendix A of this manual.

Total –– This returns the total number of inspections performed.

Faults –– This returns the total number of faults detected.

Fail High –– This returns a

1.000

when the inspection result from the

tool has exceeded the high

Fail

limit and

0.000

when the result has not

exceeded the high

Fail

limit.

Warn High –– This returns a

1.000

when the inspection result from the

tool has exceeded the high

Warn

limit (and the tool is not in a fail

condition) and

0.000

when the result has not exceeded the high

Warn

limit.

Warn Low –– This returns a

1.000

when the inspection result from the

tool has exceeded the low

Warn

limit (and the tool is not in a fail

condition) and

0.000

when the result has not exceeded the low

Warn

limit.

Fail Low –– This returns a

1.000

when the inspection result from the

tool has exceeded the low

Fail

limit and

0.000

when the result has not

exceeded the low

Fail

limit.

Result –– This returns the actual value of the inspection result; that is, the
measurement, count, or other numeric result from the gage tool. This
value corresponds to the “learned” value that appears in the “

Nominal

field of the gage tool edit panel.

Ax –– This value pertains only to a gage tool configured for linear
measurement, X or Y position, theta, wedge, or chord operations. “Ax”
returns the value of the X coordinate of Feature A.

Ay –– This value pertains only to a gage tool configured for linear
measurement, X or Y position, theta, wedge, or chord operations. “Ay”
returns the value of the Y coordinate of Feature A.

Bx –– This value pertains only to a gage tool configured for linear
measurement, wedge, or chord operations. “Bx” returns the value of the X
coordinate of Feature B.

By –– This value pertains only to a gage tool configured for linear
measurement, wedge, or chord operations. “By” returns the value of the Y
coordinate of Feature B.

*Samples –– This returns the current total number of inspection samples
since the start of run operation.