5

Chapter

Chapter 10

Environment Menu Selections

10–17

When

Freeze Last Rejects

is selected, the first rejected image will be

held on the display. While the image is frozen, subsequent rejected
images will be stored in the reject queue. Once the queue is full, the
oldest rejected image in the queue will be removed from the queue and
placed on display (in effect, an automatic resume when the queue is full).
When you select

Resume

, the CVIM2 will resume the normal image

display if the reject queue is empty; otherwise, the next image in the
queue will be removed from the queue and displayed.

Resume

When you pick

Resume

in the image display menu bar, or pick the

button in the

Freeze Modes

panel, a “frozen” image is released, and the

image updates resume.

Reject Queue Size

This field reflects the reject queue size that was selected in the

Display

panel, as indicated in Chapter 4, Inspection Configuration, on page 4–17.

Rejects Held

This field reflects the current number of reject images held in the CVIM2
system. This number, in some instances, may be one greater than the queue
size.

Inspection Results Display Panel

The main purpose of the inspection results panel is to display the results of
each inspection cycle for each tool in the associated tool set. The panel
displays the tool’s name, the pass/fail status of the previous inspection, the
cumulative total of failed inspections, and the results values of the previous
inspection. (Note: This panel is the same for both online and offline
(“setup”) operations.)

The basic display data are illustrated by the example

Results

panel shown in

Figure 10.19 (page 10–18).