Initial level 8 security setup – Rockwell Automation 5370-CVIM2 Module User Manual

Page 523

Advertising
background image

5

Chapter

Chapter 12

System Security

12–3

Since the system initially has no password file, the system security level
defaults to Level 8, and any user can access all system functions. Thus, in
order to restrict access, the system administrator should first establish a user
name
and optional password for Level 8 –– for administration access only.
This process is illustrated in Figure 12.2.

Figure 12.2 Example: Initial Security Setup –– Level 8

ЗЗЗЗЗ

ЗЗЗЗЗ

ЗЗЗЗЗ

ЗЗЗЗЗ

ЗЗЗЗЗЗ

ЗЗЗЗЗЗ

ЗЗЗЗЗЗ

ЗЗЗЗЗЗ

ЗЗЗЗЗЗ

ЗЗЗЗЗЗ

ЗЗЗЗЗЗ

ЗЗЗЗЗЗ

ЗЗЗЗЗЗ

ЗЗЗЗЗЗ

ЗЗЗЗЗЗ

ЗЗЗЗЗЗ

Once the system administrator’s Level 8 user name/password is entered, the
CVIM2 system will default to Level 1 on all subsequent power up
operations. Thereafter, the administrator must enter the Level 8 user
name/password correctly, using the appropriate uppercase and lowercase
characters, in order to gain access to Level 8 functions.

Initial Level 8 Security Setup

Advertising