Overview: profile tool configuration, Profile tool operations – Rockwell Automation 5370-CVIM2 Module User Manual

Page 393

Advertising
background image

5

Chapter

Chapter 7

Inspection Tools

7–155

The threshold setting should be the one that optimizes the profile tool for its
assigned inspection task of locating edges, counting edges, counting objects,
or measuring distances between edges, according to the tool operation
selected in the

Operation

field of the profile tool edit panel.

A profile tool can be selected when the toolset edit panel is on the screen.
Starting from the main menu bar, the selection path to this panel is as
follows: Editors

Configuration Setup Tools. This selection path

is shown by the example in Figure 7.1 (page 7–2).

Here is a summary list of the basic profile tool selection and configuration
steps, listed in their normal order of performance:

1. Select the profile tool operation.

2. Select the profile direction.

3. “Pick and place” the profile tool.

4. Select morphology filter(s), if necessary. (For details, see Chapter 8,

Thresholds, Filters, and Morphology.)

5. Set the profile threshold.

6. Select profile filters, if necessary.

7. Select the feature(s).

8. Learn the nominal value.

9. Select the ranges.

As noted earlier, there are five profile tool operations. When you pick the

Operation

field in the profile tool edit panel, the

Operation

selection panel

appears, as shown in Figure 7.127.

Figure 7.127

Operation Selection Panel for Profile Tool

Overview: Profile Tool
Configuration

Profile Tool Operations

Advertising