Camera type: selection and editing – Rockwell Automation 5370-CVIM2 Module User Manual

Page 72

Advertising
background image

5

Chapter

Chapter 3

Image Acquisition Parameters

3–33

After assigning the bank state status to the appropriate output, pick the
button to exit back to the

Acquisition System Settings

panel.

The

Camera Type

scrolling list, as shown in Figure 3.23, appears in two

places: the

Acquisition Editor

panel, and all of the

Camera

panels.

Figure 3.23 Example: Camera Type Scrolling List Panel

This list shows all of the “standard” cameras that the Allen–Bradley
Company supports, along with any number of non–standard cameras (such
as “

Camera XYZ

” in the example) that a user has configured for use with

the CVIM2 system.

The highlighted camera name in the scrolling list is the currently selected
camera type (

2801 YC

in the example). To select another name, just pick the

name. When you do, the new name is highlighted and the previous name is
unhighlighted.

In the

Acquisition Editor

panel, you can edit some of the selected camera’s

timing parameters, and you can copy a listed camera type to create a new
non–standard camera type under a different name.

In a

Camera

panel, the selected camera type should correspond to the type

that will be connected to the camera port whose number is shown in the

Camera

panel title bar (such as

“Camera 1”

). In addition, you can edit

some of the selected camera’s timing parameters.

Camera Type Edit Panel

The

Camera Type

edit panel contains several parameter selection boxes and

fields pertaining to the camera timing and scan modes for each camera type.
For the standard Allen–Bradley cameras (2801–YC, –YD, YE, and YF),
most of these parameters are inaccessible –– they cannot be changed. For
non–standard camera types, however, most of the parameters are accessible
and can be changed to whatever values are appropriate for a particular
non–standard camera.

Camera Type: Selection and
Editing

Advertising