Rockwell Automation 5370-CVIM2 Module User Manual

Page 129

Advertising
background image

5

Chapter

Chapter 4

Inspection Configuration

4–43

To store an image in a different device, enter the device name, a colon, and a
file name, such as . . .

EE:feature1

In all cases, after entering the appropriate image name in the keyboard panel,
pick the

key. When you do, the CVIM2 system begins saving the

subimage and displays this message:

Saving Image

Please Wait

When the CVIM2 system finishes saving the subimage, it displays this
message:

Done saving image

Compression ratio 2:1

The compression ratio value appearing in the message is truncated; thus, 2:1
could actually be 2.9:1. Also, the actual compression ratio value varies with
the details in the subimage. For lossless compression, however, it cannot
exceed the theoretical limit of 4:1.

After a period of time that varies according to the size of the subimage, the
“Done” message disappears and the

Image Manager

panel reappears. Note

that the newly saved image file appears as “

EE:image1 1, 55x59x8

” in

the scrolling window, as shown in Figure 4.34.

Figure 4.34 Example: Image Manager Panel After Saving Image

The “

EE:image1

” identifies the memory device and filename of the image

file. The “

1,

” indicates that the image is a gray scale image (currently, this

value is always “1”). The “

55x59x8

” indicates the image file size in pixels.

Advertising