Rockwell Automation 5370-CVIM2 Module User Manual

Page 343

Advertising
background image

5

Chapter

Chapter 7

Inspection Tools

7–105

Second Pass Configuration

The second pass configuration procedure for the feature finder tool is
identical to the same procedure for the reference window tool. Refer to the
Second Pass Configuration section of Chapter 6, page 6–46, for details.

Max. Number: Limiting Feature Recognition

The

Max. Number

selection enables you to limit the number of features that

the feature finder tool recognizes, thereby improving the tool’s efficiency and
conserving system memory.

Nominal (“Learn”) Function

The number appearing in the

Nominal

field after you pick it indicates the

number of features that matched the stored template, within the limit
imposed by the

Max. Number

setting in the tool edit panel. Thus, if six

features could match the stored template, but

Max. Number

were set to 4,

then the maximum “learn” number would be limited to 4.

When you pick the

Nominal

field, the

Feature Locations

panel appears in

the display, as shown by the example in Figure 7.87. At the same time, the
search window and one or more feature windows appear over the image. In
this example, all six of the dark objects in the search window have been
matched; thus, all six objects show feature windows.

Figure 7.87 illustrates the appearance of the

Feature Locations

panel and

the windows when using the “

Stop When First

” parameter.

Figure 7.87 Example: Feature Locations Panel (“Stop When First Feature” Enabled)

#1

#2

#3

#4

#5

#6