Rockwell Automation 5370-CVIM2 Module User Manual

Page 71

Advertising
background image

Chapter 3

Image Acquisition Parameters

3–32

Bank Switch State Output

The

Bank Switch State Output

field accesses a discrete I/O edit panel,

where you can assign the

Bank State

status signal to one of the

Module I/O

or

System I/O

outputs, and thereby enable the CVIM2 system to signal your

process equipment when a bank switch has occurred.

NOTE: The

Bank State

signal is always inactive when cameras #1, #2, and

#3 are active, and is always active when cameras #4, #5, and #6 are selected.

When you pick the

Bank Switch State Output

field in the

Acquisition

System Settings

panel, the

Module I/O

panel appears, as shown in

Figure 3.22.

Figure 3.22 Example: Assigning Bank State to Module I/O Output 2

ЗЗ

ЗЗ

ЗЗ

ЗЗ

ЗЗЗЗЗ

ЗЗЗЗЗ

ЗЗЗЗЗ

ЗЗЗЗЗ

ЗЗЗЗЗ

ЗЗЗЗЗ

ЗЗЗЗЗ

ЗЗЗЗЗ

ЗЗЗЗЗ

ЗЗЗЗЗ

ЗЗЗЗЗ

ЗЗЗЗЗ

(Note that the

Module I/O

panel always appears first by default. If you want

to assign the

Bank State

signal to a

System I/O

output, you can pick the

button to access the

I/O Device

panel, from which you can then

select the

System I/O

panel.)

As the example in Figure 3.22 illustrates, when you pick the “

Out 2

” field in

the

Module I/O

panel, “

Bank State

” appears in the field, indicating that it is

now assigned as

Module I/O

output 2. (Note that you can remove

Bank

State

from output 2 by picking the same field again.)