Chapter 7

Inspection Tools

7–56

Fail –– This returns an “error code” when the tool is in a fail condition,
and

0.000

for all other conditions. The error code identifies a specific

reason for the failure; for example, error code

1045.000

identifies “High

range fail” as the cause of the inspection failure. The complete list of
error codes and fail conditions appears in Appendix A of this manual.

Total –– This returns the total number of inspections performed.

Faults –– This returns the total number of faults detected.

Fail High –– This returns a

1.000

when the inspection result from the

tool has exceeded the high

Fail

limit and

0.000

when the result has not

exceeded the high

Fail

limit.

Warn High –– This returns a

1.000

when the inspection result from the

tool has exceeded the high

Warn

limit (and the tool is not in a fail

condition) and

0.000

when the result has not exceeded the high

Warn

limit.

Warn Low –– This returns a

1.000

when the inspection result from the

tool has exceeded the low

Warn

limit and

0.000

when the tool has not

exceeded the low

Warn

limit.

Fail Low –– This returns a

1.000

when the inspection result from the

tool has exceeded the low

Fail

limit and

0.000

when the result has not

exceeded the low

Fail

limit.

Result –– This returns the actual value of the inspection result; that is, the
count or other numeric result from the window tool. This value
corresponds to the “learned” value that appears in the “

Nominal

” field of

the window tool edit panel.

*Height#, Length#, etc. –– Each of these returns a contour measurement
value, which is available only from a window tool configured for black or
white contour operations. Figure 7.48 (page 7–55) shows how the list
appears when all of the contour measurement functions are enabled.

**Samples –– This returns the current total number of inspection samples
since the start of run operation.

**Min –– This returns the current minimum value of the inspection
results since the start of the run operation.

**Max –– This returns the current maximum value of the inspection
results since the start of the run operation.

**Sum –– This returns the current sum of all inspection results since the
start of the setup or online run operation.

**Sum2 –– This returns the current sum of the squares of all inspection
results since the start of the setup or online run operation.

*Whenever one of these contour measurement functions is selected in a math
tool formula, the “#” sign must be replaced with the appropriate object
number
when the “

Single

” operation is selected in the math tool edit panel.

Advertising