5

Chapter

Chapter 6

Reference Tools

6–5

Y only

The Y only operation consists of a single reference line that lies along the
vertical (Y) axis of the image field. Y only is appropriate in applications
where workpiece shift is expected in the Y–axis, but not in the X–axis.
Figure 6.4 shows a Y only reference line detecting Y–axis workpiece shift
and applying Y–axis shift to a line gage.

Figure 6.4 Example: Using a Y Only Reference Line Operation

Workpiece:

nominal position

Line gage:

original position

Workpiece:

position after shift

Workpiece

shift

Y–axis

reference line

Y–axis

reference line

Line gage: with Y–axis

shift compensation applied

INSPECTED

POSITION

NOMINAL

POSITION