Inspection Tools

7–153

Y Direction Profile Display

When the “

Y

” direction is selected, the variations in amplitude appear along

the Y, or vertical, axis. In this case, the left side of the profile display
represents the 0 (zero) reference point for gray scale level ranging from 0 to
255, while the right side of the display represents the average value for each
row of the processed image (maximum value: 255).

Figure 7.124 uses the same workpiece shown in Figure 7.121, rotated 90

°

clockwise, to illustrate a “

Y

” direction profile display.

Figure 7.124

Example: “Y” Direction Profile Display

Profile display:

Average gray

scale values of

each row of pixels

“0” gray scale level

Profile

amplitude