5

Chapter

Chapter 6

Reference Tools

6–49

When you pick the

button to exit the

Feature Locations

panel, the

“learned” data appear in the

Nominal

field and indicate, from left to right, an

X coordinate, a Y coordinate, and an angle (

q).

NOTE: If the warning message shown in Figure 6.41 appears after you pick
the

Nominal

field, it indicates a problem with some aspect of the feature

configuration. Pick the

button to exit this message.

Figure 6.41 Warning Message: One or More Features Not Found

If one feature is active (Feature A or Feature B), the “learned” X and Y
coordinates in the

Nominal

field identify the location of the center of the

single feature window. Since no angular measurement is involved in this
case, the angle (

q) is always 0.0°.

If two features are active (Feature A and Feature B), the “learned” X and Y
coordinates in the

Nominal

field identify the location of the midpoint on a

line connecting the centers of the two feature windows. The angle (

q)

indicates the relation of that line to the X–axis of the image field.