Chapter 6

Reference Tools

6–8

X’, X then Y

The X’, X then Y reference line operation consists of three reference lines,
two that lie along the horizontal (X) axis of the image field, and one that lies
along the vertical (Y) axis. This operation is appropriate in applications
where workpiece shift and rotation are expected.

In operation, the X’, X then Y reference line operation evaluates the two
X–axes first for X–axis shift and for rotation, using the difference in the
amount of shift along both X–axes to calculate the number of degrees of
rotation. It applies X–axis shift compensation to the Y–axis, as required,
before evaluating the Y–axis for workpiece shift. (Note that the Y–axis is not
rotated
prior to analysis.)

Figure 6.7 illustrates the three X’, X then Y reference lines detecting a
shifted and rotated workpiece, applying the X–axis shift to the Y–axis, then
detecting Y–axis shift in the same workpiece and applying the combined
X–Y shift and rotation to the associated line gage.

Figure 6.7 Example: Using the X’, X Then Y Reference Line Operation

Y–axis with X–axis shift

compensation applied

Workpiece:

nominal position

X–axis

reference line

X–axis

workpiece

shift

Line gage:

original position

X–axis

reference line

Y–axis

reference line

X–axis

reference line

X–axis

reference line

Workpiece:

position after shift

and rotation

Y–axis

workpiece

shift

Line gage: with X– and

Y–axis shift and rotation

compensation applied