Rockwell Automation 5370-CVIM2 Module User Manual

Page 262

Advertising
background image

Chapter 7

Inspection Tools

7–24

This section discusses the inspection results that are available to a math tool
formula from a gage tool. The specific set of results depends on the specific
gage tool operation. As Figure 7.23 shows, the inspection results that
correspond to any particular gage tool operation will appear in one of three
lists.

Figure 7.23 Expanded Results Lists For Gage Tools in Math Formulas

Count pixels, count

objects, count edges

X position,

Y position, theta

Linear measurement,

wedge angle, chord angle

Execute
Pass
Warn
Fail
Total
Faults
Fail High
Warn High
Warn Low
Fail Low
Result
Samples
Min
Max
Sum
Sum2

Execute
Pass
Warn
Fail
Total
Faults
Fail High
Warn High
Warn Low
Fail Low
Result
Ax
Ay
Samples
Min
Max
Sum
Sum2

Execute
Pass
Warn
Fail
Total
Faults
Fail High
Warn High
Warn Low
Fail Low
Result
Ax
Ay
Bx
By
Samples
Min
Max
Sum
Sum2

Here is a brief definition and explanation of each of the gage result types
listed in Figure 7.23:

Execute –– This returns a

1.000

when the tool has executed its inspection

task, and

0.000

for all other conditions.

Pass –– This returns a

1.000

when the tool has passed its inspection task,

and

0.000

for all other conditions.

Warn –– This returns an “error code” when the tool is in a warn
condition (and not in a fail condition) and

0.000

for all other conditions.

The error code identifies a specific reason for the warning; for example,
error code

1057.000

identifies “Low range warning” as the cause. The

complete list of error codes appears in Appendix A of this manual.

Gage Tool Inspection
Results and Math Tool
Formulas