7–77

The availability of the contrast function, and the maximum contrast values,
are both related to the specific kernel selection. Table 7.3 identifies the kernel
selections and their corresponding contrast functions and values.

Table 7.3 Summary Table of Kernels and Maximum Contrast Values

Kernel Selections

Contrast Function Enabled?

Max. Contrast Value

Sobel X

Yes

2

Sobel Y

Yes

2

Laplace

Yes

1

X Edge

Yes

3

Y Edge

Yes

3

Average 3x3

Yes

3

Average 5x5

Yes

4

User 3x3

User 5x5

Depends on the kernel configuration.

Convolution Kernels and LUT Selections

Table 7.4 correlates the convolution kernels (except the two user–
configurable kernels) with the LUTs (look–up tables). The table shows
whether a kernel produces a signed image, which contains pixel values
between –128 and +127, or an unsigned image, which contains pixel values
between 0 and +255, and it indicates which LUTs are most appropriate for
each kernel.

Table 7.4 Summary Table: Kernels and Appropriate LUTs

Convolution

Output Image:

Appropriate LUTs

Convolution

Kernel

Output Image:

Signed or Unsigned

Ident.

Sign

Abs.

Inv.

Clip

S.Clip

Thres.

S.Thr.

Sobel X

Signed

No

Yes

Yes

No

No

No

Yes

Sobel Y

Signed

No

Yes

Yes

No

No

No

Yes

Laplace

Signed

No

Yes

Yes

No

No

No

Yes

X Edge

Signed

No

Yes

Yes

No

No

No

Yes

Y Edge

Signed

No

Yes

Yes

No

No

No

Yes

Average 3x3

Unsigned

Yes

No

No

Yes

Yes

No

Yes

No

Average 5x5

Unsigned

Yes

No

No

Yes

Yes

No

Yes

No

May be useful if threshold is adjusted to remove negative values.