Chapter

Chapter 7

Inspection Tools

7–81

Figure 7.65 Example: Designating S2 Source for Image Tool Using S1 – S2

In this example,

Tool 2

is an image tool that is configured to process an AOI

within an image whose source is camera #1 (designated by “

C1

” in the “

S1

column) and deliver the processed image to a destination image buffer
(designated by “

P1

” in the “

Dest

” column).

Tool 3

is an image tool that is configured for the

S1 – S2

image subtraction

operation. Its primary image source is camera #1 (designated by “

C1

” in the

S1

” column). Its secondary image source is the destination image buffer

containing the processed image from

Tool 2

(designated by “

P1

” in the “

S2

column). The destination for

Tool 3

’s processed image is a different

destination image buffer (designated by “

P2

” in the “

Dest

” column).

Tool 4

is a window tool. Its primary (and only) image source is the

destination image buffer (designated by “

P2

” in the “

S1

” column) that

contains the results of the image subtraction operation performed by the
preceding image tool,

Tool 3.

When the

S1 – S2

subtraction operation is selected for

Tool 3

, the

and

buttons both become active in the tool edit panel. The

button accesses the “pick and place” function for AOI#1, which

relates to image source

S1

, while the

button accesses the “pick and

place” function for AOI#2, which relates to image source

S2

.

Initially, AOI#1 appears in its default position in the upper–left part of the
screen. The image content within AOI#1 at this point depends on whether
any part of AOI#2 lies outside its source image (which is from the AOI in

Tool 2

, in this example). If not, the contents of AOI#1 will immediately

display a processed image from the

S1 – S2

subtraction; if so, the contents

of AOI#1 will remain unchanged. (See the Image Tool Operations: Warning
Messages
section, on page 7–84, for a discussion of the automatic
adjustments that the CVIM2 system performs on the AOI’s under some
circumstances, and the related “warning” messages.)

AOI#1 and AOI#2 can be resized and/or positioned at this time by picking
their respective “

P&P

” buttons to access their pick and place functions.