Rockwell Automation 5370-CVIM2 Module User Manual

Page 418

Advertising
background image

Chapter 7

Inspection Tools

7–180

Figure 7.145 (A) appears when the “

Statistics

” option has not been selected

for the corresponding tool, while (B) appears when the “

Statistics

” option

has been selected (and inspection data has been acquired). Note that (B)
applies only to tools for which this option is available.

The

Ranges

selection panel contains a number of fields, which are

described briefly as follows:

Nominal –– The reading in this field is the “nominal” or learned value
that results when you pick the

Nominal

field in the

Tool Edit

panel. It is

included in this panel as a convenience for setting the range limits.

Fail High –– Use this field to set the upper “fail” limit.

Warn High –– Use this field to set the upper “warning” limit.

Warn Low –– Use this field to set the lower “warning” limit.

Fail Low –– Use this field to set the lower “fail” limit.

For tools with ranges, the CVIM2 system compares the inspection results
value to the range limits selected for that tool. The tool status is a function of
where an inspection results value lies in relation to the range limits, as
illustrated in Figure 7.146.

Figure 7.146 Relation of Ranges to Tool Status

Fail

Warn

Pass

Warn

Fail

Fail High

Warn High

Warn Low

Fail Low

Tool Status

T

Inspection Results