Rockwell Automation 5370-CVIM2 Module User Manual

Page 354

Advertising
background image

Chapter 7

Inspection Tools

7–116

Results

When you pick the

key, the

Results

panel appears, as shown by the

example in Figure 7.92.

Figure 7.92 Example: Results Panel

The

Results

panel provides three scrolling lists, whose functions are

described as follows:

The left list contains all of the toolsets in the current configuration. The
list illustrated in Figure 7.92 contains

Toolset 1

and

Toolset 2

, which are

the two toolsets in the current configuration. The function of the left list is
to enable the user to select inspection results from any toolset within the
current configuration.

The center list contains the basic results sources from the current
inspection cycle that are available to a math tool formula. The list
illustrated in Figure 7.92 contains the basic results sources for

Toolset 2

,

as follows:

— “

Missed

” refers to the missed trigger counter. When it is selected in a

math formula, “

Missed

” returns the current missed trigger counter for

the toolset.

— “

In1

through

In4

” refers to discrete I/O inputs that must be configured

in the

Discrete I/O Editor

panel before they can have any effect in a

math tool formula. When one of these inputs is selected in a math
formula, it returns the state of the corresponding input line as a logic
“1” or logic “0.”

— “

Execute Group#

” refers to the execution status of a group of tools

that precedes the math tool in the toolset edit panel (see Figure 7.90 on
page 7–111). The group number (1 to 32) is specified by the “#” sign.
This result source returns a logic “1” if any one tool in the group
executes during the inspection cycle, and a logic “0” if no tool in the
group executes.

Advertising