5

Chapter

Chapter 4

Inspection Configuration

4–23

Figure 4.16 Display Menu Example

The

Display

menu determines the appearance of the setup mode

image/tool display panel during tool evaluation. The five sections in this
menu have these meanings:

•

The top section enables you to save an image in compressed form, and
reload the image later.

•

The second section enables you to reset counters and statistics in the
results panels and the results detail panels.

•

The third section determines what will appear in the display panel
during tool evaluation operations: all enabled inspection tools, the
failed tools only, or the camera image only.

•

The fourth section appears only when two or three camera inputs have
been assigned to the current toolset’s trigger.

•

The bottom section enables you to start (and stop) the tool evaluation
operations.

Note that a cursor (➤) points to

All Tools

, while another cursor points to

Camera 1

. These are the current default settings for the display mode

and camera selections.

5. Pick

Go

. When you do, the image/tool display panel is enabled, with

these results:

•

If the

Auto

trigger source is selected, a continuous series of camera

images will appear on the screen immediately, such as is shown in
Figure 4.17 (page 4–24).

•

If an external trigger source is selected, the system must receive a
trigger signal in order to display a camera image.

•

If inspection tools had been previously configured (and

All Tools

selected), those tools would also appear at this time.

Advertising