Rockwell Automation 5370-CVIM2 Module User Manual

Page 109

Advertising
background image

5

Chapter

Chapter 4

Inspection Configuration

4–23

Figure 4.16 Display Menu Example

The

Display

menu determines the appearance of the setup mode

image/tool display panel during tool evaluation. The five sections in this
menu have these meanings:

The top section enables you to save an image in compressed form, and
reload the image later.

The second section enables you to reset counters and statistics in the
results panels and the results detail panels.

The third section determines what will appear in the display panel
during tool evaluation operations: all enabled inspection tools, the
failed tools only, or the camera image only.

The fourth section appears only when two or three camera inputs have
been assigned to the current toolset’s trigger.

The bottom section enables you to start (and stop) the tool evaluation
operations.

Note that a cursor (➤) points to

All Tools

, while another cursor points to

Camera 1

. These are the current default settings for the display mode

and camera selections.

5. Pick

Go

. When you do, the image/tool display panel is enabled, with

these results:

If the

Auto

trigger source is selected, a continuous series of camera

images will appear on the screen immediately, such as is shown in
Figure 4.17 (page 4–24).

If an external trigger source is selected, the system must receive a
trigger signal in order to display a camera image.

If inspection tools had been previously configured (and

All Tools

selected), those tools would also appear at this time.

Advertising