Rockwell Automation 5370-CVIM2 Module User Manual

Page 378

Advertising
background image

Chapter 7

Inspection Tools

7–140

Figure 7.107 Example: Four Window Tools Configured to Corner Objects

The formula is set up on the formula entry keyboard as shown in
Figure 7.108.

Figure 7.108 Example: Formula Configured to Sum Results From Four Window Tools

With the formula set up as shown in Figure 7.108, when you pick the

Nominal

field in the math tool edit panel, the system performs one “test”

operation of the formula and returns a total of 4.000.

By setting the window tools’

Fail High

and

Fail Low

range limits to 1.000,

each window tool will yield a “Pass” condition if it detects a single object, or
a “Fail” result if it detects no object, or more than one object.

By setting the math tool’s

Fail High

and

Fail Low

range limits to 4.000, the

math tool will yield a “Pass” condition if all four windows detect a single
object, or a “Fail” result is any window fails.

Advertising