5

Chapter

Chapter 7

Inspection Tools

7–37

NOTE: You can change the status of each measurement function to either
active or inactive, according to whether it is required for a particular
inspection application.

When you pick an active measurement function name in the measurement
configuration table, such as “

Area

,” a “

Target

” slide bar panel appears, as

illustrated by the “

Target Area

” slide bar panel in Figure 7.33.

Figure 7.33 Example: Selecting “Target” Slide Bar Panel for Area Measurement Limits

ЗЗЗЗЗЗЗ

ЗЗЗЗЗЗЗ

ЗЗЗЗЗЗЗ

ЗЗЗЗЗЗЗ

Here is a brief description of each item in the slide bar panel. (The

Target

Area

slide bar panel serves as an example for the other measurement

functions, since they all use the same kind of slide bar panel.)

Slide bar –– The function of the slide bar cursors is to set high (“

Max

”)

and low (“

Min

”) limits for the area of the contours that you want to be

counted as objects.

Max –– Picking this field enables you to enter directly the maximum area
(in pixels) of the contours to be counted as objects. This is used in place
of the slide bar to enter values directly and will also rescale the slide bar
on the basis of the value entered.

Min –– Picking this field enables you to enter directly the minimum area
(in pixels) of the contours to be counted as objects. This is used in place
of the slide bar to enter values directly and will also rescale the slide bar
on the basis of the value entered.

Done –– When you pick the

button, the system exits back to the

Target

panel.

Advertising