3–15

Here is a brief definition and explanation of each of the expanded result
types listed in Figure 3.10.

Pass –– This returns a

1.000

when the tool has passed its inspection task,

and

0.000

for all other conditions.

Warn –– This returns a “error code” when the tool is in a warn condition
(and not in a fail condition) and

0.000

for all other conditions. The error

code identifies a specific reason for the warning; for example, error code

1057.000

identifies “Low range warning” as the cause. The complete list

of error codes and warn conditions appears in Appendix A of this manual.

Fail –– This returns a “error code” when the tool is in a fail condition and

0.000

for all other conditions. The error code identifies a specific reason

for the failure; for example, error code

1045.000

identifies “High range

fail” as the cause of the inspection failure. The complete list of error
codes and fail conditions appears in Appendix A of this manual.

Fail High –– This returns a

1.000

when the inspection result from the

tool has exceeded the high

Fail

limit and

0.000

when the result has not

exceeded the high

Fail

limit.

Warn High –– This returns a

1.000

when the inspection result from the

tool has exceeded the high

Warn

limit (and the tool is not in a fail

condition) and

0.000

when the result has not exceeded the high

Warn

limit.

Warn Low –– This returns a

1.000

when the inspection result from the

tool has exceeded the low

Warn

limit (and the tool is not in a fail

condition) and

0.000

when the result has not exceeded the low

Warn

limit.

Fail Low –– This returns a

1.000

when the inspection result from the

tool has exceeded the low

Fail

limit and

0.000

when the result has not

exceeded the low

Fail

limit.

Result –– This returns the actual value of the light probe result; that is,
the luminance value from the light probe tool. This value corresponds to
the “learned” value that appears in the “

Nominal

” field of the

Light

Probe

panel. Light probe results can range from 0.000 (darkest) to

255.000 (lightest).

*Samples –– This returns the current total number of inspection samples
since the start of run operation.

*Min –– This returns the current minimum value of the inspection results
since the start of the run operation.

*Max –– This returns the current maximum value of the inspection results
since the start of the run operation.

*Sum –– This returns the current sum of all inspection results since the
start of the setup or online run operation.

*Sum2 –– This returns the current sum of the squares of all inspection
results since the start of the setup or online run operation.