Rockwell Automation 5370-CVIM2 Module User Manual

Page 420

Advertising
background image

Chapter 7

Inspection Tools

7–182

Here is a summary of the conditions under which tool fail and tool warn
conditions can occur.

A tool fail condition arises from the following situations:

A tool result that is greater than the

Fail High

limit (FH

t R).

A tool result that is less than the

Fail Low

limit (FL

u R).

Any other situation in which the tool cannot operate properly, such as a
reference line being unable to find a specified feature.

A tool warn condition arises from the following situations:

A tool result that is greater than the

Warn High

limit and less than or

equal to the

Fail High

limit (WH

t R x FH), and is not a tool fail

condition.

A tool result that is less than the

Warn Low

limit and greater than or

equal to the

Fail Low

limit (WL

u R y FL), and is not a tool fail

condition.

Advertising