5

Chapter

Chapter 1

Hardware Connection and Powerup Check

1–7

5. Connect the coaxial cables to the appropriate R, G, B, and SYNC

connectors on the N22 module and the monitor.

Connecting the Camera Cable: 2801–YC Camera

Use the following steps to connect the appropriate camera cable when an
Allen–Bradley 2801–YC camera is to be used:

1. Locate the appropriate camera cable, Catalog No. 2801–NC14, 15, or 16.

2. Connect one connector on the cable to the appropriate

Camera

connector on the CVIM2 front panel.

3. Connect the other connector on the cable to the appropriate connector on

the camera.

Connecting the Camera Cable: 2801–YB, –YD, and –YE Camera

Use the following steps to connect the appropriate camera cable when an
Allen–Bradley 2801–YB, –YD, or –YE camera is to be used:

1. Locate the appropriate camera cable, Catalog No. 2801–NC5, 6, or 7.

2. Connect the male connector on the cable to the appropriate

Camera

connector on the CVIM2 front panel.

3. Connect the female connector on the cable to the appropriate connector

on the camera.

Connecting the Mouse Cable

Assuming that the I/O interface cable is attached to the

Module I/O

or

System I/O

connector on the CVIM2 front panel, connect the mouse cable

to the

PORT B

connector on I/O interface box 2801–N27.

If you intend to use the

PORT A

connector, you must use a gender adapter

between the mouse cable connector and the

PORT A

connector on the I/O

interface box.

NOTE: You may need to configure the CVIM2 system to recognize the
selected mouse port connection. The mouse configuration procedure is
detailed in the Configuring CVIM2 System for Mouse Operation section on
page 1–10.