Rockwell Automation 5370-CVIM2 Module User Manual
Page 337

5
Chapter
Chapter 7
Inspection Tools
7–99
In Figure 7.83, four “morph passes” have occurred, with the result that all of
the horizontal lines are eliminated.
Figure 7.83 Example: Image Tool (Four Morph Passes)
Note that the only effect on the vertical lines has been to shorten them.
This section discusses the expanded inspection results that are available to a
math tool formula from an image tool. As Figure 7.84 shows, the expanded
inspection results for an image tool appear in one list.
Figure 7.84 Expanded Results Lists For Image Tools in Math Formulas
Execute
Pass
Warn
Fail
Total
Faults
Here is a brief definition and explanation of each of the expanded result
types listed in Figure 7.84.
•
Execute –– This returns a
1.000
when the tool has executed its inspection
task, and
0.000
for all other conditions.
•
Pass –– This returns a
1.000
when the tool has passed its inspection task,
and
0.000
for all other conditions.
•
Warn –– This always returns a
0.000
.
Image Tool Inspection
Results and Math Tool
Formulas