5

Chapter

Chapter 6

Reference Tools

6–61

When the

button is picked on the

Feature Locations

panel, the

Nomina

l field in the tool edit panel displays the X– and Y–axis coordinates

of the center of rotation (281 and 233), along with the angular position of the
index mark (227.0

°) relative to the 0° point on the X–axis. (In this example,

the index mark is located 227.0

° clockwise from the 0° point.)

At this point, the rotation finder configuration is complete, and it can be used
as a reference for inspection tools that follow it in the toolset edit panel.

Figure 6.52 illustrates the rotation finder tool in operation. In this case, (A)
shows the circular and rectangular objects in their original locations, while
(B) shows these objects after they have shifted and rotated. Note that the line
gage tool remains properly positioned over the shifted and rotated
rectangular object.

Figure 6.52 Example: Rotation Finder Tool in Operation (Setup Mode)

A

B

Advertising