6–51

•

Theta –– When a two–feature reference window tool is used, this returns
the nominal or “learned” value of the rotation angle, in degrees, between
a line connecting the centers of the two features, and the X–axis of the
image field. When one feature is used, theta returns

0.000

.

•

nX –– This returns the change from the nominal or “learned” X
coordinate of the principal reference point.

•

nY –– This returns the change from the nominal or “learned” Y
coordinate of the principal reference point.

•

nTheta –– This returns the change from the nominal or “learned” value
of the rotation angle, in degrees, between a line connecting the centers of
the two features, and the X–axis of the image field. When one feature is
used,

nTheta returns

0.000

.

•

Xc –– This returns the current X coordinate of the center of the feature
when one feature is used, or the midpoint between the centers of the two
features when two features are used.

•

Yc –– This returns the current Y coordinate of the center of the feature
when one feature is used, or the midpoint between the centers of the two
features when two features are used.