Rockwell Automation 5370-CVIM2 Module User Manual

Page 373

Advertising
background image

5

Chapter

Chapter 7

Inspection Tools

7–135

This section discusses the expanded inspection results that are available to a
math tool formula from another math tool. As Figure 7.102 shows, the
expanded inspection results for a math tool appear in one list.

Figure 7.102 Expanded Results List For Math Tools in Math Formulas

Execute
Pass
Warn
Fail
Total
Faults
Fail High
Warn High
Warn Low
Fail Low
Result
Value#
Samples
Min
Max
Sum
Sum2

Here is a brief definition and explanation of each of the expanded result
types listed in Figure 7.102.

Execute –– This returns a

1.000

when the tool has executed its inspection

task, and

0.000

for all other conditions.

Pass –– This returns a

1.000

when the tool has passed its inspection task,

and

0.000

for all other conditions.

Warn –– This returns an “error code” when the tool is in a warn
condition (and not in a fail condition) and

0.000

for all other conditions.

The error code identifies a specific reason for the warning; for example,
error code

1057.000

identifies “Low range warning” as the cause. The

complete list of error codes and warn conditions appears in Appendix A
of this manual.

Fail –– This returns an “error code” when the tool is in a fail condition
and

0.000

for all other conditions. The error code identifies a specific

reason for the failure; for example, error code

1049.000

identifies

“Could not access result” as the cause of the inspection failure. The
complete list of error codes and fail conditions appears in Appendix A of
this manual.

Total –– This returns the total number of inspections performed.

Faults –– This returns the total number of faults detected.

Math Tool Inspection
Results and Math Tool
Formulas