3–45

Source I/O –– When “

I/O

” is selected as the (external) trigger source,

this selects the discrete input in the

Discrete I/O Edit

panel.

Strobe I/O –– When a strobe light is to be used, this selects the discrete
output for the strobe trigger.

Ack I/O –– For applications requiring the trigger ACK signal, this selects
a discrete output for the signal.

Nak I/O –– For applications requiring the trigger NAK signal, this selects
a discrete output for the signal.

NOTE 1: The trigger source and signal assignments can be applied only to
cameras 1, 2, and/or 3, or cameras 4, 5, and/or 6. This is shown in
Figure 3.32. Camera #1 is selected initially by default.

Figure 3.32 Example: Inactive Camera Selections in Toolset Trigger Panel

NOTE 2: When camera 4, 5, or 6 is used, an external +24VDC power
supply must be used, as described in Chapter 1, Hardware Connection and
Powerup Check
, of this manual, and the Allen–Bradley Pyramid Integrator
Installation Manual, Publication 5000–6.2.10, which is supplied with the
Pyramid Integrator chassis.

The trigger selection field in the

Toolset Trigger

panel, shown in

Figure 3.33, offers two choices of trigger operation based on an internal
source (

Auto

) or an external source (

I/O

). Figure 3.33 shows that

Auto

is

currently selected. To “toggle” to

I/O

, pick the

Trigge

r field. To toggle back

to

Auto

, pick the field again.

Figure 3.33 Trigger Selection Field in Trigger Setup Panel