Chapter 6

Reference Tools

6–30

Active Feature Selection

For the purposes of this discussion, the configuration process begins with the
selection of the “active feature”; that is,

Feature A

or

Feature B

. The

selected feature is “active” for the purposes of configuration.

Feature Image Configuration

The next step is the configuration and selection of a feature image (or no
image, which disables the feature). A feature image is a “template,” stored in
a file, that the reference window tool uses to locate a specific feature in the
search window. This step is initiated when you pick the

Image Name

field

in the reference window tool edit panel (see Figure 6.24).

Selecting Image Manager Panel

When you pick the

Image Name

field in the tool edit panel, the

Image

Manager

panel appears, as shown in Figure 6.25.

Figure 6.25 Selecting Image Manager Panel

The function of the

Image Manager

panel is to provide a number of choices

for compressing and storing images. (This panel is discussed in detail in
Chapter 4, Inspection Configuration, under the Image Manager Panel
heading on page 4–40.)

As it is used with reference windows, the

Image Manager

panel is restricted

to compressing and storing subimages only. Also, the “

Lossless

” (default)

compression method is normally used since reference window feature images
are usually quite small, and compressing them further does not save a
significant amount of memory. Furthermore, any loss of feature image data
(that would result from using the “

Baseline

” compression method) may

make the operation of the reference window less reliable. Finally, the

Predictor

and

Point Xform

selections should remain at their default values

of 4 and 0, respectively.