Max–Offset Mode
When you pick
Max–Offset
in the
Thresh Mode
panel, the
Threshold
panel appears as shown in Figure 7.143.
Figure 7.143 Appearance of Threshold Adjustment Panel With Max–Offset Mode
In this mode, the slide bar has two cursors (the
n and
Low
cursors) and two
corresponding fields (the
Offset
and
Limit
fields). The default value for the
“
Offset
” field is 128, and the default value for the “
Limit
” field is 0.
The
Max–Offset
threshold mode enables you to set up a dynamic threshold,
along with a minimum limit below which the threshold may not go during the
run mode operation.
The concept of the
Max–Offset
threshold mode is identical to the concept of
the
Min+Offset
threshold mode, except that the threshold has a low limit