5

Chapter

Chapter 7

Inspection Tools

7–51

Note that the maximum measurable angle in each direction is 90.0

°

(clockwise) and –90.0

° (counterclockwise), since there is no provision for

resolving the direction of the major axis. For example, if the object in
Figure 7.43 (A) were to rotate counterclockwise past the –90.0

° point, its

theta would become positive.

NOTE: Although the angle values appear in the

Pick Target

panel with an

apparent accuracy of one place to the right of the decimal, the actual values
available to the math tool are stored with the full floating point accuracy.

H Size, L Size –– The

L Size

contour measurement function returns the size,

in pixels, of an object’s major axis, while the

H Size

function returns the

size of an object’s minor axis, as illustrated in Figure 7.45.

Figure 7.45 Example: H Size and L Size Contour Measurement Functions

L Size

H Size

NOTE: These measurement functions are active only for Catalog No.
5370–CVIM2AC, which is a CVIM2 module equipped with an Advanced
Contour Extractor (ACE) daughter board.