Method

The method selection determines the location of a midpoint offset. The two
available choices are these:

Midpoint

and

Weighted

.

When you pick the

Method

field (

Feature

selection panel) successively, the

selection toggles to the opposite method. Thus,

Midpoint

changes to

Weighted

, and vice versa.

Figure 7.135 compares the two methods. In this example, the profile window
is positioned around two dark objects that are asymmetrical; thus, each
objects’ “center of gravity” is skewed toward its right side. The threshold is
set near the top of the profile image so the profile tool can detect the extreme
left edge of each object.

Figure 7.135 Example: Comparing the Midpoint and Weighted Methods

Threshold
(level 217)

A

B

Offset

marker

Offset

marker

When

Midpoint

is selected, the midpoint offset will be located exactly

midway between the edges of an object, as illustrated by Figure 7.135 (A).
When

Weighted

is selected, the offset is skewed rightward, toward the

center of gravity of the object, as illustrated by Figure 7.135 (B).