Chapter 7
Inspection Tools
7–74
Figure 7.62 Example: Effect of Average 5x5 Kernel on Inspected Object
Image
tool
Inspected
object
User 3x3, User 5x5 Kernels
The
User 3x3
and
User 5x5
kernels can be configured with coefficient
values that the user deems most appropriate for a specific inspection
application. Initially, these kernels are configured in the “identity” mode; that
is, the center coefficient is 1 and all other coefficients are 0, as shown below:
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
The result of these “identity” coefficients is that they have no effect on the
pixels in the image.
When you pick
User 3x3
or
User 5x5
in the
Image Kernel
selection panel,
the
button becomes active, as shown in Figure 7.63 (page 7–75).
When you then pick the
button, the
User Kernel
setup panel
appears, also shown in Figure 7.63.