Mc_readactualtorque, Parameters – Yaskawa MotionWorks IEC User Manual
Page 131

PLCopenPlus Function Blocks for Motion Control 2013-04-13
123
MC_ReadActualTorque
This Function Block returns the value of the actual torque or force in
percentage of rated torque. Note that peak torque will vary from 200 to
over 300% based on the specific amplifier model.
Parameters
Parameter
Data
type
Description
VAR_IN_OUT
B
Axis
Logical axis reference. This value can be located on the Configuration
tab in the Hardware Configuration (logical axis number).
VAR_INPUT
Default
B
Enable
BOOL
The function will continue to execute while
enable is held high.
FALSE
VAR_OUTPUT
B
Valid
BOOL
Indicates that the outputs of the function are valid.
B
Busy
BOOL
Set high upon the rising edge of the 'Execute' or 'Enable' input, and
reset if Done, CommandAborted, or Error is true.
B
Error
BOOL
Set high if error has occurred during the execution of the function
block. This output is cleared when 'Execute' or 'Enable' goes low.