Yaskawa MotionWorks IEC User Manual

Page 338

Advertising
background image

PLCopenPlus Function Blocks for Motion Control 2013-04-13

330

Mechatrolink

4312

001E

Reserved

Mechatrolink

4312

001F

Reserved

Mechatrolink

4312

0022

Reserved

Mechatrolink

4312

0023

Reserved

Mechatrolink

4312

0024

Reserved

Mechatrolink

4312

0025

Reserved

Mechatrolink

4312

0026

Reserved

Mechatrolink

4312

0094

Reserved

Mechatrolink

4312

0095

Reserved

Mechatrolink

4312

0096

Reserved

Mechatrolink

4312

00E5

Reserved

app

4401

0008

Each call to groupAxes() must be matched by a
corresponding call to ungroupAxes(). If a script exits
without such a matching call (thus leaving an 'orphaned'
group behind), this warning is issued. Clearing the
warning also ungroups the orphaned group.

app

4401

0009

The debug stack trace was longer than expected. It may
be clipped.

app

4403

0001

The event queue for the remote client was full, and an
event was dropped. This is generally caused either by
exceeding the network bandwidth or exceeding the
general system processing power (starving the
connection). When an event is dropped in this manner,
the connection is terminated.

app

4403

0005

An RMI connection was attempted by an external client
and rejected due to the concurrent connection limit.

app

4407

0001

The configuration file directory is read-only or resides on a
read-only file system. Attempts to update the
configuration or create directories will fail.

app

4407

0002

An attempt was made to write to a read-only configuration
file. The write failed.

app

4407

0105

There was an indication that the SRAM battery backup
power may have failed temporarily. SRAM data may have
been compromised.

app

4408

0001

The alarm history was configured to use NVRAM storage,
but either the available NVRAM was not sufficient to
contain the configured buffer size, or the configured buffer
size was not large enough to contain the configured
number of records. The alarm history will contain fewer
records than configured.

app

4408

0002

The alarm history was configured to use NVRAM storage