Yaskawa MotionWorks IEC User Manual

Page 313

Advertising
background image

PLCopenPlus Function Blocks for Motion Control 2013-04-13

305

until the alarm condition is cleared.

motionKernel

3202

0005

Axis Coordinate System: The command acceleration was
greater than the allowable range for the axis in the
positive direction. The axis may not be moved again until
the alarm condition is cleared.

motionKernel

3202

0006

Axis Coordinate System: The command acceleration was
greater than the allowable range for the axis in the
negative direction. The axis may not be moved again until
the alarm condition is cleared.

motionKernel

3202

0007

Axis Coordinate System: The command torque was
greater than the allowable range for the axis in the
positive direction (overtorque). The axis may not be
moved again until the alarm condition is cleared.

motionKernel

3202

0008

Axis Coordinate System: The command torque was
greater than the allowable range for the axis in the
negative direction (overtorque). The axis may not be
moved again until the alarm condition is cleared.

motionKernel

3202

0011

Joint Coordinate System: The command position was
outside the allowable range for the axis in the positive
direction (positive overtravel). The axis may not be moved
again until the alarm condition is cleared. After the alarm
is cleared, it is permissible to execute a move which
brings the axis back toward the allowed region, even
though the axis is probably still outside the allowed
region. Any move which pulls the axis further away from
the allowed region will re-trigger the alarm.

motionKernel

3202

0012

Joint Coordinate System: The command position was
outside the allowable range for the axis in the negative
direction (negative overtravel). The axis may not be
moved again until the alarm condition is cleared. After the
alarm is cleared, it is permissible to execute a move which
brings the axis back toward the allowed region, even
though the axis is probably still outside the allowed
region. Any move which pulls the axis further away from
the allowed region will re-trigger the alarm.

motionKernel

3202

0013

Joint Coordinate System: The command speed was
greater than the allowable range for the axis in the
positive direction (overspeed). The axis may not be
moved again until the alarm condition is cleared.

motionKernel

3202

0014

Joint Coordinate System: The command speed was
greater than the allowable range for the axis in the
negative direction (overspeed). The axis may not be
moved again until the alarm condition is cleared.

Advertising