PLCopenPlus Function Blocks for Motion Control 2013-04-13

313

limited (default) access.

app

3406

0002

The default login group for the web server was assigned to
a group which did not exist. Access control has been
disabled, because a minimal amount of access is required
in order to log in. The configuration file should be fixed
before continuing.

app

3406

0003

The web server configuration specified access control
should be enabled, but did not specify at least one path to
control access to. Access control has been disabled. The
configuration file should be fixed before continuing.

app

3407

0002

The base directory for configuration files was missing and
has been created automatically. The system has booted in
a minimal configuration mode, and most functionality is
limited. Please upload a new complete configuration file
set.

app

3407

0003

A required default configuration file was missing. A
minimal configuration for the corresponding component
has been loaded, and some functionality may be limited.

app

3407

0004

A required default configuration file was incorrectly
formatted. A minimal configuration for the corresponding
component has been loaded, and some functionality may
be disabled.

app

3407

0005

A configuration file specified by the user configuration file
set was incorrectly formatted. The corresponding default
configuration file is being used instead.

app

3407

0006

The file describing which configuration set to use was
corrupted. The default configuration set is being used.

app

3407

0007

An error occurred while writing a config file. The file
system may be full or damaged.

app

3407

0101

The configured RAM disk on the controller was unable to
be created.

app

3407

0102

Detected an unsupported option card inserted in the
controller.

app

3407

0104

Data in the controller SRAM did not match the expected
value. It should be treated as corrupted until it is re-
initialized.

app

3407

0106

The SRAM battery backup power failed. SRAM data should
be treated as corrupted until it is re-initialized.

app

3407

0107

The controller's time-of-day clock detected a voltage
decrease in the backup battery. The current time and date
is likely to be incorrect. This alarm can be cleared, but will
recur when the controller is powered ON until the time