PLCopenPlus Function Blocks for Motion Control 2013-04-13

319

app

340C

0204

Unable to reach the network for the EtherNet/IP server.
Common causes include: invalid remote server address,
invalid gateway, invalid subnet mask, or the Ethernet
network is not correctly configured.

app

340C

0205

Remote server rejected connection attempt. The remote
server may not be listening for connections or there may
be a firewall preventing the connection.

app

340C

0206

The Ethernet/IP client ran out of connection slot
resources. Reduce the number of concurrent client
connections.

app

340C

0302

Unable to connect to the Modbus TCP slave. Common
causes include: invalid Modbus TCP slave address, invalid
gateway, invalid subnet mask, or the Ethernet network is
not correctly configured.

app

340C

0303

There is no route to the Modbus TCP slave. Common
causes include: invalid Modbus TCP slave address, invalid
gateway, invalid subnet mask, or the Ethernet network is
not correctly configured.

app

340C

0304

Unable to reach the network for the Modbus TCP slave.
Common causes include: invalid Modbus TCP slave
address, invalid gateway, invalid subnet mask, or the
Ethernet network is not correctly configured.

app

340C

0305

Modbus TCP slave rejected connection attempt. The
Modbus TCP slave may not be listening for connections or
there may be a firewall preventing the connection.

app

340C

0306

The Modbus TCP master ran out of connection slot
resources. Reduce the number of concurrent slave
connections.

app

340C

1020

The controller battery voltage has dropped, indicating it
has failed or is about to fail. While the controller is
powered on, the battery should be replaced as soon as
possible or a prolonged power-down state will cause
various static data to be lost.

app

340C

1028

The driver parameter specified in the axis configuration
caused an exception

app

340C

1029

The driver parameter did not match the axis configuration

app

340C

1030

The configured axis count exceeded the allowable limit.

app

340C

1031

The axis count exceeded the allowable limit due to an
auto-detected axis.

app

340C

1033

Using an incompatible version of the PLCopenPlus
firmware function block library may result in controller
instability. Consequently, the PLC application will not be

Advertising