Notes, Error description – Yaskawa MotionWorks IEC User Manual

Page 197

Advertising
background image

PLCopenPlus Function Blocks for Motion Control 2013-04-13

189

B

Value

LREAL

The drive parameter value

LREAL#0.0

VAR_OUTPUT

B

Done

BOOL

Set high when the commanded action has been completed
successfully. If another block takes control before the action is
completed, the Done output will not be set. This output is reset
when execute goes low.

B

Busy

BOOL

Set high upon the rising edge of the 'Execute' or 'Enable' input,
and reset if Done, CommandAborted, or Error is true.

B

Error

BOOL

Set high if error has occurred during the execution of the function
block. This output is cleared when 'Execute' or 'Enable' goes low.

E

ErrorID

UINT

If error is true, this output provides the Error ID. This output is
reset when 'Execute' or 'Enable' goes low.

Notes

Refer to parameters with LREAL Data Type in the

Axis Parameter List

.

Error Description

ErrorID

Meaning

0

No Error

4378

The function block is not applicable for the external axis
specified

4402

The scan compensation delay parameter 1305 is only valid for
external encoders.

4403

The High Speed Output functionality is only available on
external encoders.

4410

Parameter is read-only.

4625

Axis ID does not correspond to an axis configured on the
system. Verify the value of AxisNum matches a logical axis
number in the configuration. Tip: Make sure AXIS_REF is
properly declared as a VAR or VAR_GLOBAL in all relevant
POUs.

4648

The parameter number does not exist for the specified axis