PLCopenPlus Function Blocks for Motion Control 2013-04-13

126

MC_ReadActualVelocity

This Function Block returns the value of the actual velocity of the axis in
user units / sec as configured in the Hardware Configuration.

Parameters

Parameter

Data type

Description

VAR_IN_OUT

B

Axis

AXIS_REF

Logical axis reference. This value can be located on the
Configuration tab in the Hardware Configuration (logical
axis number).

VAR_INPUT

Default

B

Enable

BOOL

The function will continue to
execute while enable is held high.

FALSE

VAR_OUTPUT

B

Valid

BOOL

Indicates that the outputs of the function are valid.

E

Busy

BOOL

Set high upon the rising edge of the 'Execute' or 'Enable'
input, and reset if Done, CommandAborted, or Error is
true.

B

Error

BOOL

Set high if error has occurred during the execution of the

Advertising