308

motionKernel

3202

0038

The move specified would exceed the software torque
limits in the negative direction and was rejected before
being started. The group may be moved again
immediately if desired.

motionKernel

3202

0039

The predictive soft limit encountered a segment that
doesn't support the predicted stopping point.

motionKernel

3202

0041

Cam and Contour tables must have a header indicating
the number of rows and columns and a feed forward
velocity flag. Comma separated data values following the
header.

motionKernel

3202

0042

In CamTables, the first (master) column must be either
increasing or decreasing.

motionKernel

3202

0043

In ContourTables, the first (time) column must start at
zero and be increasing.

motionKernel

3202

0044

The master position was outside the range of the
CamTable, which automatically stopped the cam motion.

motionKernel

3202

0045

One or more slave axes could not attain the target
position and velocity within the user specified time limit
for the Cam or Gear motion.

motionKernel

3202

0046

One or more slave axes could not attain the target
position and velocity within the user specified distance
limit for the Cam or Gear motion.

motionKernel

3202

0051

Axis enable failed. This problem is usually a result of
communication problems with the servo drive.

motionKernel

3202

0052

Runtime computation detected an invalid motion
parameter. This alarm ID can occur if a discrete move
has to be completed but the commanded deceleration for
that move is not sufficient. For example if a MoveAbsolute
aborts another move and the axis has to stop at a position
that will come up in a couple of scans, but the
deceleration input on the MoveAbsolute is not high enough
to make the desired profile, this alarm will occur.

motionKernel

3202

0061

The axis Positive Overtravel (P-OT) limit has been
exceeded. Motion is prevented in the positive direction.
The axis may not be moved again until the alarm
condition is cleared.

motionKernel

3202

0062

The axis Negative Overtravel (N-OT) limit has been
exceeded. Motion is prevented in the negative direction.
The axis may not be moved again until the alarm
condition is cleared.

motionKernel

3202

0100

The inverse kinematics computation detected a world
position that can not be reached.