Yaskawa MotionWorks IEC User Manual

Page 333

Advertising
background image

PLCopenPlus Function Blocks for Motion Control 2013-04-13

325

axis may not be moved again until the alarm condition is
cleared.

motionKernel

4202

0011

The command position will soon reach the allowable range
for the axis in the positive direction (positive overtravel).
The axis may not be moved again until the alarm
condition is cleared. After the alarm is cleared, it is
permissible to execute a move which brings the axis back
toward the allowed region, even though the axis is
probably still outside the allowed region. Any move which
pulls the axis further away from the allowed region will re-
trigger the alarm.

motionKernel

4202

0012

The command position will soon reach the allowable range
for the axis in the negative direction (negative overtravel).
The axis may not be moved again until the alarm
condition is cleared. After the alarm is cleared, it is
permissible to execute a move which brings the axis back
toward the allowed region, even though the axis is
probably still outside the allowed region. Any move which
pulls the axis further away from the allowed region will re-
trigger the alarm.

motionKernel

4202

0013

The command speed will soon reach the allowable range
for the axis in the positive direction (overspeed). The axis
may not be moved again until the alarm condition is
cleared.

motionKernel

4202

0014

The command speed will soon reach the allowable range
for the axis in the negative direction (overspeed). The axis
may not be moved again until the alarm condition is
cleared.

motionKernel

4202

0015

The command acceleration will soon reach the allowable
range for the axis in the positive direction. The axis may
not be moved again until the alarm condition is cleared.

motionKernel

4202

0016

The command acceleration will soon reach the allowable
range for the axis in the negative direction. The axis may
not be moved again until the alarm condition is cleared.

motionKernel

4202

0017

The command torque will soon reach the allowable range
for the axis in the positive direction (overtorque). The axis
may not be moved again until the alarm condition is
cleared.

motionKernel

4202

0018

The command torque will soon reach the allowable range
for the axis in the negative direction (overtorque). The
axis may not be moved again until the alarm condition is
cleared.

motionKernel

4202

0021

The command position will soon reach the allowable range

Advertising