PLCopenPlus Function Blocks for Motion Control 2013-04-13

233

Y_DirectControl

This block allows direct access to any of three possible control modes
available on the specified axis. Y_DirectControl makes it possible to
perform open loop velocity control for winding applications. In position
mode, the IEC application program can apply an algorithm to directly
command the position at every scan.

Parameters

Parameter

Data type

Description

VAR_IN_OUT

B

Axis

AXIS_REF

Logical axis reference. This value can be located on the
Configuration tab in the Hardware Configuration (logical axis
number).