Yaskawa MotionWorks IEC User Manual
Page 70

PLCopenPlus Function Blocks for Motion Control 2013-04-13
62
source. See
VAR_INPUT
Default
B Execute
BOOL
Upon the rising
edge, all other
function block inputs
are read and the
function is initiated.
To modify an input,
change the value
and re-trigger the
execute input.
FALSE
VAR_OUTPUT
B Done
BOOL
Set high when the commanded
action has been completed
successfully. If another block takes
control before the action is
completed, the Done output will not
be set. This output is reset when
execute goes low.
B Busy
BOOL
Set high upon the rising edge of the
'Execute' or 'Enable' input, and
reset if Done, CommandAborted, or
Error is true.
B Error
BOOL
Set high if error has occurred during
the execution of the function block.
This output is cleared when
'Execute' or 'Enable' goes low.
E ErrorID
UINT
If error is true, this output provides
the Error ID. This output is reset