PLCopenPlus Function Blocks for Motion Control 2013-04-13

62

source. See

MC_TouchProbe

VAR_INPUT

Default

B Execute

BOOL

Upon the rising
edge, all other
function block inputs
are read and the
function is initiated.
To modify an input,
change the value
and re-trigger the
execute input.

FALSE

VAR_OUTPUT
B Done

BOOL

Set high when the commanded
action has been completed
successfully. If another block takes
control before the action is
completed, the Done output will not
be set. This output is reset when
execute goes low.

B Busy

BOOL

Set high upon the rising edge of the
'Execute' or 'Enable' input, and
reset if Done, CommandAborted, or
Error is true.

B Error

BOOL

Set high if error has occurred during
the execution of the function block.
This output is cleared when
'Execute' or 'Enable' goes low.

E ErrorID

UINT

If error is true, this output provides
the Error ID. This output is reset