Yaskawa MotionWorks IEC User Manual

Page 315

Advertising
background image

PLCopenPlus Function Blocks for Motion Control 2013-04-13

307

greater than the allowable range for the axis in the
positive direction. The axis may not be moved again until
the alarm condition is cleared.

motionKernel

3202

0026

World Coordinate System: The command acceleration was
greater than the allowable range for the axis in the
negative direction. The axis may not be moved again until
the alarm condition is cleared.

motionKernel

3202

0027

World Coordinate System: The command torque was
greater than the allowable range for the axis in the
positive direction (overtorque). The axis may not be
moved again until the alarm condition is cleared.

motionKernel

3202

0028

World Coordinate System: The command torque was
greater than the allowable range for the axis in the
negative direction (overtorque). The axis may not be
moved again until the alarm condition is cleared.

motionKernel

3202

0031

The move specified would exceed the software position
limits in the positive direction and was rejected before
being started. The group may be moved again
immediately if desired.

motionKernel

3202

0032

The move specified would exceed the software position
limits in the negative direction and was rejected before
being started. The group may be moved again
immediately if desired.

motionKernel

3202

0033

The move specified would exceed the software speed
limits in the positive direction and was rejected before
being started. The group may be moved again
immediately if desired.

motionKernel

3202

0034

The move specified would exceed the software speed
limits in the negative direction and was rejected before
being started. The group may be moved again
immediately if desired.

motionKernel

3202

0035

The move specified would exceed the software
acceleration limits in the positive direction and was
rejected before being started. The group may be moved
again immediately if desired.

motionKernel

3202

0036

The move specified would exceed the software
acceleration limits in the negative direction and was
rejected before being started. The group may be moved
again immediately if desired.

motionKernel

3202

0037

The move specified would exceed the software torque
limits in the positive direction and was rejected before
being started. The group may be moved again
immediately if desired.

Advertising