PLCopenPlus Function Blocks for Motion Control 2013-04-13

258

Y_ReadMultipleParameters

This function will read a number of controller parameters at once. The
parameters must be an LREAL type. Populate the parameter numbers into
the ParamStruct, and the function block will supply the values to the
requested parameters.

Refer to parameters with LREAL Data Type in the

Axis Parameter List

.

Parameters

Parameter

Data

type

Description

VAR_IN_OUT

B

Axis

AXIS_REF

Logical axis reference. This value can be located on the Configuration
tab in the Hardware Configuration (logical axis number).

V

ParamStruct

PrmStruct

Structure containing a list of parameter numbers to be read and their
corresponding values

VAR_INPUT

Default

B

Enable

BOOL

The function will continue to execute while
enable is held high.

FALSE

VAR_OUTPUT

B

Valid

BOOL

Indicates that the outputs of the function are valid.

E

Busy

BOOL

Set high upon the rising edge of the 'Execute' or 'Enable' input, and
reset if Done, CommandAborted, or Error is true.

B

Error

BOOL

Set high if error has occurred during the execution of the function block.
This output is cleared when 'Execute' or 'Enable' goes low.

E

ErrorID

UINT

If error is true, this output provides the Error ID. This output is reset
when 'Execute' or 'Enable' goes low.

V

ErrorPrm

UINT

If there was an error while attempting to read one of the parameters
listed in the ParamStruct, this output will contain the offending
parameter number.