Commissioning

Basic terms of positioning

Device structure and interfaces to the higher−level control

6

l

109

EDBCSXP064 EN 8.0

The following control interfaces are available for the controller under code C4010:

ƒ

Automation interface (AIF) X1
– 4 process data words (in conjunction with the EMF2192IB EtherCAT

communication module, sync−controlled via the terminal X6/DI1)

ƒ

MotionBus (CAN) connection X4
– CAN1 (process data object 1, PDO1, sync−controlled)
– CAN3 (process data object 3, PDO3, cyclic)

ƒ

System bus (CANaux) connection X14
– CANaux1 (process data object 1, PDO1, sync−controlled)
– CANaux2 (process data object 2, PDO2, cyclic)

ƒ

Control via codes C4040, C4041, C4042 through a parameter data channel, e.g. AIF,
CAN, CAN−AUX, LECOM (for commissioning and test purposes)

The interface between the control and the ECSxP axis module is mainly determined by the
control word (Ctrl1) and the two status words (Stat1) and (Stat2). They contain all control
and status bits required for controlling the process.

The most important control bits from the control: (

158):

Bit

Designation

Function

3

Quick stop (QSP)

Quick stop

4

PNoSet_1

Selection of the positioning profile (binary coded)

5

PNoSet_2

6

PNoSet_4

7

PNoSet_8

8

ProfEnable

Start of the selected positioning profile

9

CINH

Controller inhibit

11

TripReset

Reset fault message

12

JogCCW

Manual jog (inching mode)

13

JogCW

The most important status bits ("Stat1") to the control (

161):

Bit

Designation

Function

6

PNoAct_1

Feedback of the currently active positioning profile (binary coded)

7

PNoAct_2

8

PNoAct_4

9

PNoAct_8

13

HomePosAvailable

Home position known

14

InTarget

Positioning target reached

15

DwellTime

The dwell time has expired after profile generator setpoint has reached the
target position.